MacLean Dixie HFS


Towers > Towers and Guyed Structures

Print Page
Home > Towers > Towers and Guyed Structures

Power Hub (PH) Guy/Tension Anchors

 

 

 

 1-3/8" Solid Hub Anchors

Features:

  • Used for normal soils
  • Hub is 1.375 inch square and rated at 6,000 ft-lbs.
  • Drive end of the standard power installed anchor installing tool torque tube for 1.375 hubs engages over the square hub
  • All of the power installed anchor rods are used with this anchor.

Application:

  • Assemble the rod to the hub.
  • Insert the anchor with rod into the torque tube and fully engage to the tool locking assembly.
  • Installed in line with the guy per the specific anchor instruction

Material:

  • Coated with rust inhibitor

 

 

 


1-3/8" Square Solid Hub - 6000 Ft-Lbs Ultimate Installing Torque: For Standard Installing Tool
Catalog Number Helix Size in (mm) Tapped for Rod Size (inches) Weight Ea (lbs)
D84-6 8 3/4 or 1 10
D104-6 10 3/4 or 1 13
 

 

 

 2-1/4" Turbo Drive®  (patent pending)

 

 

 

 

Features:

  • One piece cast steel hub for increased torque and bending strength
  • Four flute hub to break up tough soils
  • 10,000 ft-lb torque rating
  • Light duty with 3/8" helix thickness
  • Heavy Duty with 1/2" helix thickness
  • Use with standard 10,000 ft-lb installing tool (5-1/4" bolt circle tool) or 15,000 ft-lb installing tool (7-5/8" bolt circle)

Application:

  • Assemble the rod to the socket drive helix hub
  • Insert the anchor with rod into the torque tube and fully engage to the tool locking assembly
  • Installed in line with the guy per the specific anchor instruction

Material:

  • Coated with rust inhibitor

Std. Duty 2-1/4" Turbo Drive ® Socket Drive - 10,000 ft-lb Ultimate Installing Torque; 1/2" helix for Standard Installing Tool
Catalog Number Helix Size in (mm) Tapped for Rod Size (inches) Weight Ea (lbs)
TD225-84 8 3/4 or 1 11.2
TD225-104 10 3/4 or 1 14.2
TD225-114 12 3/4 or 1 17.9
TD225-134 14 3/4 or 1 22.4
 

Heavy Duty 2-1/4" Turbo Drive® Socket Drive - 10,000 ft-lb Ultimate Installing Torque 1/2" Helix for Std. Installing Tool
Catalog Number Helix Size in (mm) Tapped for Rod Size (inches) Weight Ea (lbs)
TDH225-84 8 3/4 or 1 12.7
TDH225-104 10 3/4 or 1 16.7
TDH225-114 12 3/4 or 1 21.6
TDH225-134 14 3/4 or 1 27
 

 

 PH Rod with Eyenut Assembly

 

 

1 Inch Diameter 36,000 LB Ultimate Tensile Strength, Rod with assembled eyenut
Catalog Number Eyenut Type Length (ft.)* Weight Ea (lbs)
D100T Triple Eyenut 7 17.7
 


MacLean Civil

©2019 MacLean Civil HFS

Web site design and web site development by Americaneagle.com